Service manual
14
13VT-N100
13VT-N150
13VT-CN10
Table - B
PART
REPLACED
ADJUSTMENT
NECESSARY UNNECESSARY
NOTE
IC2001 X
IC401 X
IC2101 X
CRT X
ADJUSTMENT
ITEM
DATA
INTIAL VALUE RANGE
ADJUSTMENT
COMMENTS
*No adjustment is required due to proper setting being made by IC2001 automatically.
Table - A
PICTURE 16 0~63
TINT 39 0~77
COLOR 13 0~63
BRIGHT 32 0~63
SHARP 7 0~13
PHASE 0 0~7
H-PHASE 20 0~31
RF-AGC 18 0~63
V-AMP 32 0~63
PIF-VCO 40 0~127
R CUT-OFF 0 0~255
G CUT -OFF 0 0~255
B CUT-OFF 0 0~255
G GAIN 128 0~255
B GAIN 128 0~255
MUTE 0 0~2 "0"= Normal raster, "1"= no"Y",
"2"= No Vertical
ENERGY SAVE 45 0~45
BALANCE 32 0~63
TEXT BOX 15 0~127
TEXT PICTURE 20 0~80
CCD LEVEL 7 0~10
OPTION 39 0~63 13VT-N100/150 Must be set to "39"
Data is stored in IC2003.
The adjustment is needed to compensate for characteristics
of parts including IC401.
Initial setting values are written from IC2001. Adjust for best
results.
Adjust items related to picture tube only.