Specification

Description
Dimensions
APart # D E F G H
Performance
Materials
Specication Data
33°F
160°F
125 psi
Minimum working temperature
Maximum working temperature
Maximum working pressure
Installation Requirements
Page 2 of 2
Steel
Zinc
DZR LF Brass ¹
EPDM
PTFE
DZR LF Brass ¹
DZR LF Brass ¹
ABS
Copper
DZR Brass
DZR LF Brass ¹
Screw
Handle
Spindle
O-ring
Seat
Ball
Body
Cover
Olive
Cap
End Plug
1/2 In. PTC X 3/4 In. GHT x 60 In.
26004
2.55
60.56
0.97
1.44
1.11
0.49
60.0
1.21
1
2
3
4
5
6
7
8
9
10
11
¹ Lead Free for all models, surfaces that are in contact with consumable water contain less
than 0.25% lead by weight.
All measurements are displayed in inches
Fitting Size Nominal Pipe Size
Insertion Depth
Pipe OD Insertion Depth(in)
1/2 in. 1/2 in. CTS 5/8 in. 0.95
Pipe Type
1.Turn off water supply, and drain the line.
2.Cut pipe square or remove existing valve and disconnect supply
line.
3.Remove burrs from inside and outside of pipe.
4.Mark 0.95-in insertion depth on pipe using depth gauge tool.
5.Secure valve to stud or mounting bracket.
6.Push pipe into valve to insertion depth mark.
7.Connect and tighten supply line to washing machine.
8.Turn on water and check connections.
# 26004
SharkBite Universal fittings are intended to be a permanent
connection and are not designed for repeated connection and
disconnection after the initial install.
SharkBite Fitting Reuse
1/2 in. spacing between ends of completed Connections
Minimum Distance Between Fittings
Codes and Standards
ASME A112.18.1
CSA B125.1-12
NSF/ANSI/CAN 61
NSF/ANSI 372
US 1 877 700 4242 | sales@sharkbite.com | sharkbite.com
Canada 1 888 820 0120 | c
anadasales@rwc.com
B
C
Tu
b
ing: Hard drawn copper pipe Type K, L and M and
annealed Type M not to exceed 3/8 nominal complying
with ASTM B 88, PEX tubing complying with ASTM F 876
or
CS
A B137.5, or CVPC tubing complying with ASTM D
2846 o
r CSA B137.6, PE-RT tubing complying with ASTM
F2769 or CSA B137.18
SSTBraiding12
PVCHose Liner
11