ASSE 1061 TESTING 
Below are some of the testing that SharkBite fittings 
Hydrostatic Burst: 
Fittings and pipe assembled and raised to min burst pressures at temperatures below: 
PEX 
Nominal Tubing Size 
in. 
PSI @ 73.4 ˚F 
PSI @ 180 ˚F 
1/4 PEX 
752 
336 
1/2 PEX 
480 
215 
5/8 and larger PEX 
475 
210 
Hydrostatic Sustained Pressure: 
Fittings and pipe assembled and raised to min burst pressures at temperatures below: 
PEX 
Nominal Tubing Size 
in. 
PSI @ 180 ˚F 
Duration 
1/4 PEX 
305 
1000 h 
1/2 PEX 
195 
1000 h 
5/8 and larger PEX 
190 
1000 h 
CPVC 
Nominal Tubing Size 
PSI @ 180 ˚F 
Duration 
All 
521 
6 m 
All 
364 
4 h 
Copper 
Nominal Tubing Size 
PSI @ 200 ˚F 
Duration 
All 
400 
1000 h 