Operator`s manual

SHARK SSD DIESEL • #97-6167 • REV. 7/05
7
PRESSURE WASHER
OPERATOR’S MANUAL
ASSEMBLY INSTRUCTIONS
STEP 1: Attach the high pressure
hose to the spray gun using teflon
tape on hose threads.
STEP 3: Release the coupler collar
and push the nozzle until the collar
clicks. Pull the nozzle to make sure
it is seated properly.
STEP 5: Connect the high pressure
hose to the pump discharge fitting.
Push coupler collar forward until se-
cure.
STEP 2: Pull the spring-loaded col-
lar of the wand coupler back to in-
sert your choice of pressure nozzle.
STEP 6: Connect one end of garden
hose to the cold water source.
STEP7: Connect the other end of the
garden hose to pump water inlet. In-
spect inlets. CAUTION: Do not run
the pump without water or pump
damage will result.
Safety
Latch
Spray
Gun
High Pressure
Hose
Wand
Coupler
Pressure
Nozzle
Pressure
Nozzle
Wand Coupler
Wand Collar
Discharge
Fitting
Cold Water
Source
Garden Hose
Water
Inlet
Garden
Hose
Coupler Collar
DipStick
STEP 4: Remove shipping cap and
install oil dipstick. Check pump oil
level by using dipstick or observe oil
level in oil window (if equipped). Use
30 wt. non detergent oil.