Operator`s manual

13.2.6. FILTER MENU
FILTER MENU Level 3
Total 276 25 mV
Metal 34 12 % 154.26°
MENU
EXIT
TEST
IFS/HACCP
PRODUCT
MOZZARELLA
OK
5
VIBRATION mV
5
VIBRATION FILTER
off
BP FILTER CCF
LP FILTER off
GF MODE off
The FILTER MENU sets  lters to improve the detection reliabil-
ity and suppress noise.
VIBRATION mV
(E160)
TosetVIBRATION mV:
1. Set PRODUCT 000, AMP X% 100, AMP Y% 100
2. Run the production line or the conveyor, but without products and without
metal.
3. Read out the peak mV level.
4. Set VIBRATION mV to the maximum peak mV level plus 30%.
Default: 10
Range: 3 - 2,000
VIBRATION
FILTER (E165)
blanks out mechanical vibrations of the sensor head.
yes activates vibration  lter.
The value of VIBRATION mV (above) controls the  lter strength:
VIBRATION mVincreased: Better suppression of vibration noise, lower detection
sensitivity.
VIBRATION mVdecreased: Less suppression of vibration noise, better detection
sensitivity.
Default: no
BP FILTER
(E170)
Note:OnlychangethislterwhenadvisedbyCASSEL.
no  lter =  lter is deactivated. Do not use unless clearly instructed by CASSEL
FFT = special Filter mode. Do not use unless clearly instructed by CASSEL
CCF = default
Default: CCF
LP FILTER
(E175)
yes = Lowpass  lter activated.
Default: yes
GF MODE
(E180)
yes enables fast metal detection. Gives a wide speed range. (for GF or fast
applications)
no = normal applications
Default: no (conveyor applications with de ned belt speed)
yes (applications with unde ned speed)
yes (all gravity feed applications)
78
METAL SHARK® 2 Operator’s Manual
Software Version 1.10a and higher