User's Manual
Table Of Contents
Keypad & Proximity Reader Installation Manual
Parts
o 1 - reader
o 1 - Installation manual
Required Tools
o Up to 9 wire splices (pigtail)
o Cable, 5-9 conductor (Weigand or RS232), 24 AWG shielded (pigtail)
o Linear DC power supply
o Gang box (optional)
o Security tool for anti tamper screw
Mounting
1. Fasten the metal base plate to the wall with two or four
screws to the wall or gang box (optional)
1 (gang
box not included).
2. Clip the top edge of the cover
2, followed by the
bottom edge of the reader
3.
3. Secure the reader to the base plate by fastening the
security screw at the base of the reader
4.
Installation is completed.
Specifications
Input voltage
(Reader end)
DC10V~15V
Average read range
> 6cm
Operating current
160mA (max)
Maximum cable length
150m
Operating
temperature
-30ºC~70 ºC
Number pad format
4 bits burst by
default
Recommendations
1. Linear DC Power Supply
2. 22AWG shielded cable; “One-point” ground recommended (refer to diagram)
Wiring
Color Label Description
Red +12VDC Power Supply to reader
Black GND Signal GND
Green Data0 Wiegand Output data, D0
White Data1 Wiegand Output data, D1
Yellow RED LED RED LED control, active low
Blue Green LED Green LED control, active low