User's Manual
Low Frequency Mullion Mount Reader Installation Manual
Power up Sequences:
1. When reader is powered up, the reader will flash in Green for 5 seconds . Then the Reader is ready.
2. Blue back lit stays on when the reader is ready.
3. When card is present and read by the reader, blue back lit will flash once; and buzzer will beep once as well. The card data will then transmit to the controller. After, weather the back lit of the reader
will remain ON or Flash or change to Green or Red color, this shall depend on the Green and Red LED inputs.
Physical Dimension:
Troubleshooting:
Trouble List Solution
No Response
when Power Up
Discount the power and confirm that the power supply cable is
correctly connected (See “Wiring” above).
Check the input voltage is sufficient (See “Specifications” above).
Auto Restart
Check the input voltage is sufficient (See “Specifications” above).
Cannot read card
number correctly
Check the format setting on the controller if it is the same as the card
format. Use approved card (known format and Facility Code) to test.
Check if the shield cable is correctly connected to Classis Ground at
ONE point only.
Reader beeps but
No card data info
Check if data 0 & data 1 cable is correctly connected (See “Wiring”
above).
Check the input voltage at the card reader end is correct (See
“Specifications” above).
Buzzer error Check if the buzzer cable is correctly connected (See “Wiring” above).
Back Lit Error
Check the Led cable is correctly connected (See “Wiring” above).
Use Default Configuration Card to set it back to normal.