User's Manual

Smart Machine Smart Decision
SIM5360A_User_Manual_V1.03 2014-07-03
45
Figure 29: EXT CODEC to MODULE timing
Figure 30: MODULE to EXT CODEC timing
Table 26: Timing parameters
Parameter Description Min Typ Max Unit
T(auxsync) AUX_PCM_SYNC cycle time 125 - μs
T(auxsynch) AUX_PCM_SYNC high time 62.4 62.5 - μs
T(auxsyncl) AUX_PCM_SYNC low time 62.4 62.5 - μs
T(auxclk)* AUX_PCM_CLK cycle time - 7.8 μs
T(auxclkh) AUX_PCM_CLK high time 3.8 3.9 μs
T(auxclkl) AUX_PCM_CLK low time 3.8 3.9 μs
T(suauxsync)
AUX_PCM_SYNC setup time high before
falling edge of PCM_CLK
1.95 μs
T(hauxsync) AUX_PCM SYNC hold time after falling edge 1.95 μs