User's Manual

Smart Machine Smart Decision
SIM5360A_User_Manual_V1.03 2014-07-03
32
Figure 20: Reference circuit of level shift
To comply with RS-232-C protocol, the RS-232-C level shifter chip should be used to connect SIM5360A
to the RS-232-C interface. In this connection, the TTL level and RS-232-C level are converted mutually.
SIMCom recommends that user uses the SP3238ECA chip with a full modem. For more information
please refers to the RS-232-C chip datasheet.
Note: SIM5360A supports the baud rate: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600,
115200, 230400, 460800, 921600, 3200000, 3686400, 4000000bps. Default rate is 115200bps.
3.4 SD/MMC Interface
SIM5360A provides one 4-bit SD/MMC interface. Its operation voltage is 2.85V, with clock rates up to 52
MHz. It supports 1-bit SD/MMC or 4-bit SD data transmission mode. Though the same hardware
controller is used, the initialization procession for SD or MMC cards is different. SIM5360A will detect
which card is inserted automatically.
Note: Interface with SD/MMC memory cards up to 32GB.
3.4.1 Pin Description
Table 10: Pin description
Pin name Pin No. Function
SD_DATA0
22
SD/MMC card data0
SD_DATA1
23
SD card data1
SD_DATA2
24
SD card data2
SD_DATA3
25
SD card data3
SD_CLK
26 SD card clock
SD_CMD
21 SD card command