User's Manual

Smart Machine Smart Decision
SIM5360A_User_Manual_V1.03 2014-07-03
28
Figure 15: Power off timing sequence
Table 7: Power off timing
Symbol Parameter
Time value
Min. Typ. Max. Unit
Toff The time pulling POWERKEY down to power off 0.5 - 5 s
TpD- The time to indicate disconnecting from the network - - 2 s
Tpw- The time to indicate the module power off completely - - 2 s
Tuart The time to disable UART - - 3 s
Tusb The time to disable USB - - 2 s
Trestart The time to power on again after Tpw- 0 - - s
User can also use the AT command
AT+ CP OF to power down the module. After that, the AT commands
cannot be executed any longer. The module enters the POWER DOWN mode, only the RTC is still active.
For details, refer to Document [1].
3.3 UART Interface
SIM5360A provides two UARTs (universal asynchronous serial transmission) port. UART1 consists of a
flexible 7-wire serial interface. UART2 consists of 2-wire serial interface. The module is as the DCE (Data