User's Manual

SIM800H Document
- 8 -
DCS 1800
PCS 1900
PCL=0 205
mA PCL=7 130
PCL=15 115
Data mode
GPRS(3Rx,2Tx)
GSM 850
EGSM 900
PCL=5 440
mA PCL=12 185
PCL=19 130
DCS 1800
PCS 1900
PCL=0 300
mA PCL=7 155
PCL=15 122
I
VBAT-peak
Peak current During Tx burst 2 A
3.7. Electro-Static Discharge
SIM800H is an ESD sensitive component, so more attention should be paid to the procedure of handling and
packaging. The ESD test results are shown in the following table.
Table 7: The ESD characteristics (Temperature: 25, Humidity: 45 %)
Pin Contact discharge Air discharge
VBAT ±6KV ±12KV
GND ±6KV ±12KV
RXD, TXD ±2KV ±8KV
Antenna port ±5KV ±10KV
SPK_P/SPK_N/MIC_P/MIC_N
±2KV ±5KV
PWRKEY ±2KV ±8KV
4. Radio Characteristics
4.1. Module RF Output Power
The following table shows the module conducted output power, it is followed by the 3GPP TS 05.05 technical
specification requirement.
Table 8: SIM800H GSM 900 and GSM 850 conducted RF output power
GSM850EGSM900
PCL Nominal output power (dBm)
Tolerance (dB) for conditions
Normal Extreme