Module Conditions CNo(dB/Hz) Current(mA)
Leak current when power
off
Not accessible /
No Fix / 23.5
-130dBm/Tracking 38-39 21.8
-140dBm/Tracking 28-29 21.7
-150dBm/Tracking 18-19 20.6
-160dBm/Tracking 13-14 19.8
-130dBm/Cold start 41-42 24.7
-140dBm/Cold start 31-32 24.9
By
instrument
-150dBm/Cold start / 23.2
Leak current when power
off
Not accessible /
No Fix / 21
Searching / 19.4
Real
networking
Fixed 35 19.7
* In above table the current consumption value is the typical one of the module tested in laboratory. In the mass
production stage, there may be differences among each individual.
3.7. Electro-Static Discharge
SIM808 is an ESD sensitive component, so more attention should be paid to the procedure of handling and
packaging. The ESD test results are shown in the following table.
Table 8: The ESD characteristics (Temperature: 25, Humidity: 45 %)
Pin Contact discharge Air discharge
VBAT ±5KV ±10KV
GND ±5KV ±10KV