User's Manual

Smart Machine Smart Decision
SIM5320_Hardware Design_V1.01 2011-11-10
24
4.7 K
47K
Turn on/ off impulse
POWER_ ON
Power
on / off logic
200K
1.8V
MODULE
Figure 15: Power on Timing Sequence
Table 5: Power on timing
Parameter Description Time value Unit
Ton The time to pull POWER_ON down to power on 64< Ton<180 ms
TpD+ The time to indicate connecting with the network >5.5 s
Tpw+
The time to indicate the module is powered on
completely
>4.5 s
Tuart The time to enable UART >4.7 s
Tusb The time to enable USB >9 s