Installation Instructions
SIM5216A _HD_V1.02 Hardware Design
SIM5216A _HD_V1.02 26.08.2010
45
Figure 25: Camera module interface
NOTE
:
The data and clock lines of camera are sensitive for the capacitors. Generally the
capacitance of the ESD component is too big, if those ESD components are put on to the
parallel line then the signal will fade a lot. In order to improve the ESD performance, some
10pF capacitor can be put on data and clock lines for ESD. If one like to choose smaller
capacitance ESD component, it should be smaller than 10pF.
Figure 26: Camera module interface with analog sensor