Installation Instructions
SIM5216A _HD_V1.02 Hardware Design
SIM5216A _HD_V1.02 26.08.2010
21
Note1: Ton >= 64ms.
Note2: Commonly, the AT command can be set 2-3S after the SIM5216A is powered on.
If VBAT was supplied to SIM5216A, SIM5216A could be automatically powered on by
connecting the Power ON pin to Low level directly. In automatically powering on mode, it is
suggested that the SIM5216A should reset by RESET pin after power on. Below is the reference
circuit.
Figure 6: Automatic power on
Note: The POWER_ON has been pulled up with a 250kR resistor to VBAT in module. Make
sure that VILmax=0.2*VBAT, and the value of R1 above can be changed as you want.
In automatically powering on mode, it is suggested that the SIM5216A should reset by RESET
pin after power on.
3.4.2 Turn off SIM5216A
Following procedure can be used to turn off the SIM5216A:
z Normal power down procedure: Turn off SIM5216A using the POWER_ON pin
z Normal power down procedure: Turn off SIM5216A using AT command
3.4.2.1 Turn off SIM5216A using the POWER_ON pin (Power down)
You can turn off the SIM5216A by driving the POWER_ON to a low level voltage for period
time. The low level period of the POWER_ON is about 64mS.
This procedure will let the module to be logged off from the network and allow the software to
enter into a secure state and save data before completely disconnecting the power supply.
3.4.2.2 Turn off SIM5216A using AT command
You can use AT command
“AT+CPOF” to turn off the module. This command will let the
module to be logged off from the network and allow the software to enter into a secure state and
save data before completely disconnecting the power supply.
After this moment, the AT commands can not be executed. The module enters the POWER
DOWN mode, only the RTC is still active.
Please refer to AT command manual for details of the AT command
“AT+ CP OF ”.