KFR‐510 PackageVibrationTest
1) Type of Vibration: Random
4
1) RF performance should meet the
measure specification.
Willdowhenvolumeproduction
started
2) Duration: 60 minutes for each axis
2) The function of key components
should be normal after the test.
3) Frequency: 5~500Hz
3) ID part shouldn't be cracked or other
damage.
4) Acceleration: 1.88G
5) DUT status: Power-off
6) Axis: X, Y, Z axis
KFR‐800 TumblerTest(Multidrop
test)
1) Height of drop: 0.5m (Free drop onto wooden floor)
3 1)Thefunctionofkeycomponents
shouldbenormalafterthetest.
Y(T3)
2)Appearanceshouldn'tbecrackedor
otherdamage.
2) Number of drop: 50 time on random faces.
3)Batterycoverorbatteryseparate
fromhandsetisallowed(ifany)
3) DUT status: with battery inserted
4)It'sacceptablethatrecoverthe
separationbetweenupperandbottom
panelsexceptcrack.
Crystaloscillation
frequency
ReplacebatterieswithDCsupplyandmeasure
frequencyat2.1/3.0Vunder0/25/45degC
32MHZ+/‐3.2KHZ Y(T2)
Oscillationstopvoltage ReplacebatterieswithDCsupplyandmeasure
minimumvoltage
2.2Vorless Y(T2)
Presstest
100Nwith4mmsquaredpinonrandomplacesofthe
device.
Nomechanical,electricaland
functionalfailuresareallowed
Y(T1)
Keyforce
按键力测试
Pressbuttonwitha4.5mmdiameterpinandmeasur e
keyforceuntilLEDlit.
用 4.5mm 直径针按遥控器按键,测试按键力直至
LED 指示灯亮
170g+/‐30g
作用力在 170+/‐30g
Y(T1)
Batteryinsertandremove
test
电池拆装测试
Perform50timesofinsert/removetestroutinewith
humanfinger
人工进行 50 次电池拆装测试
3 Thefunctionofthebatterycontact
shouldbenormalafterthetest.
测试后电池接点功能正常,接触良好
Y(T3)