User's Manual

PropertyofTCPInc
ProprietaryandConfidential
 
d) Start the battery life test by pressing the on/off button at 9
sec interval, monitor voltage and check LED/light-bulb on/off
until battery die.
  


7 PrintedMaterialStrengthTest
1) Test times: 100 times (1 time= from one side to the other )
 4
1) No sign of peeling shall be appeared.

 
2) Liquor: Alcohol 95%
 
 
3) Pressure: 500g/cm
2
at less
  

  
8 SaltSprayTest
1)喷雾液:5%NaClPH=6
 4 >2HNoSignofcorrosiontometal
2实验室温度 35饱和空气桶温度 47
 
3喷雾量:1.3ml/80cm
2
/H
 
     
9 BatteryDoorTest Openandclose50times4 BatteryDoorshouldbeabletofunction
normallywithoutbecomingloose


10 EffectiveRFrange 1)Atleast70m(lineofsight)withoutRangeExtender(PA),
bulbat1mheight,remote1.01.2m
  RFrange>75 m

11 RFPower Signaldirectlyinputinstrument
3dBm


12 RFFrequency RFradiobasedonIEEE802.15.4(2.405‐2.485GHz)2.4052.485GHZ

13 Buttonfunctiontest Testfunctionofallbuttonstoworkwith4lightbulbsButtonfunctionOK

14 Nominalvoltage Testoperatingvoltagetoworkwithapairedlightbulb.2.13.0V

15 Standbycurrent Measurecurrentinstandbymodeat3.0V<2uA(tobeconfirmedafter1st500build)

16 Operatingcurrent Measurecurrentinoperationmodewhen5LEDsturnonat
3.0V
  <35mA(tobeconfirmedafter1st500build)

17 Electricaldischargetest Airdischargevolt=8kV,contactdischarge=4kVNofunctionalfailuresandnopartsshould
sufferdamage,acc.ToEN6100042
performancecriteriaB

