User's Manual

12
Microcontroller Subsystem
Typical and maximum current consumption in Run mode, code with data processing
running from Flash memory (ART accelerator enabled) or RAM
Symbol
Conditions
f
HCLK
Running Mode
Sleep Mode
Unit
T
A
=25°C
T
A
=25°C
I
MCU
External clock, all
peripherals enabled
120MHz
49
38
mA
90MHz
38
30
60MHz
26
20
30MHz
14
11
25MHz
11
8
16MHz
8
6
8MHz
5
3.6
4MHz
3
2.4
2MHz
2
1.9
External clock, all
peripherals disabled
120MHz
21
8
90MHz
17
7
60MHz
12
5
30MHz
7
3.5
25MHz
5
2.5
16MHz
4
2.1
8MHz
2.5
1.7
4MHz
2
1.5
2MHz
1.6
1.4
Typical and maximum current consumptions in Stop mode
Symbol
Parameter
Conditions
Typ
Max
Unit
T
A
=25°C
T
A
=25°C
I
MCU
Supply current in
Stop mode with
main regulator in
Run mode
Flash in Stop mode, low-speed and
high-speed internal RC oscillators and
high-speed oscillator OFF (no
independent watchdog).
0.55
1.2
mA
Flash in Deep power down mode, low-
speed and high-speed internal RC
oscillators and high-speed oscillator OFF
(no independent watchdog).
0.5
1.2
Supply current in
Stop mode with
main regulator in
Low Power mode
Flash in Stop mode, low-speed and
high-speed internal RC oscillators and
high-speed oscillator OFF (no
independent watchdog).
0.35
1.1
Flash in Deep power down mode, low-
speed and high-speed internal RC
oscillators and high-speed oscillator OFF
(no independent watchdog).
0.3
1.1