User's Manual

18
Table11.Tem perat ureandhumidityindicatorCARDS
z Humidity indicator CARDS and baking several ways as follow:
When opened, if the temperature and humidity indicator CARDS read 30%, 40%, 50%, three
colors are blue, to continue to bake for 2 hours for module;
When opened, if the humidity indicator CARDS read 30% color ring into pink, need to continue
to bake module 4 hours;
When opened, if the humidity indicator CARDS read into 30%, 40%, color ring into pink, need to
continue to bake for 6 hours module;
When opened, if the humidity indicator CARDS read into 30%, 40%, 50% are pink color ring,
need to continue to bake for 12 hours module;
When opened, if the humidity indicator CARDS read into 10%, 20%, 30% ,40%are pink