Schematics
Report No.: I20W00023-WWAN_Rev1
Chongqing Academy of Information and Communication Technology
Address
:
No. 8,Yuma Road, Chayuan New City, Nan’an District, Chongqing, P. R. China,401336
Tel: 0086-23-88069965 FAX:0086-23-88608777
Page 529 of 585
529
5.8 Peak to Average Ratio
Specifications:
FCC Part 24.232, 27.50
DUT Serial Number:
866884045632254
Test conditions:
Ambient Temperature:15℃-35℃
Relative Humidity:30%-60%
Air pressure: 86-106kPa
Test Results:
Pass
Limit
The EUT meets the requirement of having a peak to average ratio of less than 13dB.
Measurement Uncertainty:
Item
Uncertainty
Expanded Uncertainty
0.52 dB (k=2)
Test Setup
During the test, the EUT was controlled via the Wireless Communications Test Set to ensure max
power transmission and proper modulation and measured by spectrum analyzer.
Test Method
The transmitter output was connected to a CMW500 through a coaxial RF cable and directional
coupler, and configured to operate at maximum power. The peak to average ratio was measured at
the required operating frequencies in each Band on the Spectrum Analyzer.
Note: Only worst case result is given below.