Specifications

L506 Hardware Design
Copyright© Shanghai Mobiletek Communication Ltd 62
NOTES: For product handling, storage, processing, IPC / JEDEC J-STD-020C must be
followed
6.4 Baking Requirements
Due to the humidity sensitive characteristics of the L506 module, the L506 is a vacuum packaging,
which can be stored for 6 months without damage to the package, and the ambient temperature is less
than 40 C and the relative humidity is less than 90%. To meet one of the following conditions, the
process of reflow soldering should be performed before the full bake (if trays are used, please note
whether the tray is heat-resistant.), or the module may cause permanent damage to the process.
1Vacuum packing damage or leakage
2The module is exposed in the air for 168 hours or more
3The module is exposed in air for 168 hours, not meet the temperature <30 degrees and
relative humidity of the environment conditions <60%
Table6-3:Baking requirements
Baking temperature
Humidity
Baking time
120°C±5°C
<5%
4 Hours
Note: The original packaging of the module cannot bear the high temperature of baking. The
packaging needs to be removed before baking, otherwise the packaging will be damaged.