User's Manual

Page 11
5. GETTING STARTED WITH SURVCE 3
Configure the LT500
1. Go to Start menu --> Settings --> System
2. Select External GPS icon
3. On the Software port tab: select COM4
4. Then on the Hardware port tab: select COM3 and Baud: 57600
Start SurvCE 3:
1. Go to GPS Rover, in Current tab--> choose Manufacturer CHC, Model:
LT500
2. In Comms tab, select Cable, Port COM3 and Baud 57600 automatically.
3. In Receiver tab, choose the relevant antenna type and input other
information (Note: Position Rate is limited to 1 Hz).
4. In RTK tab, use Data Collector Internet as Device type, and input the
Network information to connect to NTRIP, then tick the right green icon
to establish the connection.