User's Guide

Configuring Through a Web Browser
41
For Reference Latitude and Reference Longitude:
There are mainly three methods to enter the reference coordinates and shown as
follows:
a) Acquire Current Position: Click this button to acquire current position obtained
through autonomous positioning automatically.
b) Manual Input: Manually input the coordinate of a control point.
c) From CORS: After the receiver logging in CORS, the software can record the
coordinate of current position based on fix solution.
For Sample for Average:
Users can determine the positioning limit and sampling amount. The positioning limit
falls into two types:
a) Single Solution Coordinates: Collect the coordinates of receiver obtained
through autonomous positioning.
b) Fixed Solution Coordinates: Only collect coordinates of receiver with a fixed
solution.
After the configuration of positioning limit and sampling amount, click to carry
out sampling and averaging the progress bar will show the progress the result