Use Manual

3. Front panel operation
i70 GNSS Receiver User Guide Page 25
to 9920.
OK
Click Enter button to save the settings and back
to the top-level menu, and then this working
mode will take effect.
Cancel
Click Enter button to cancel the settings and back
to the second-level menu.
Base APIS & Cable
Set up the receiver as a base station using
both APIS service and external UHF.
Click Enter button to enter the
configuration screen.
Mode Base APIS & Cable
The title of this configuration screen.
Way Cable & APIS
Indicates that the receiver is set up as a base
station using not only external UHF, but also APIS
service
Format CMR
Click Enter button to change the correction
format.
The available correction formats are: CMR,
CMR+, SCMR, RTCM v2.3, RTCM v3, and
RTCM v3.2.
IP 211.144.118.5
Click Enter button to enter Common IP
screen.
In Common IP screen, click Fn button to
move to the line of IP address, and then
click Enter button to change to other
predefined IP address. After the IP address
has been changed, you can click Fn button
to move to OK field, and then click Enter
button to save the change and back to the
second-level menu; or click Fn button to
move to Cancel field and click Enter button
to cancel the change and back to the
second-level menu.
Port 9901
Click Enter button to change the port from 9901
to 9920.
OK
Click Enter button to save the settings and back
to the top-level menu, and then this combination
working mode will take effect.
Cancel
Click Enter button to cancel the settings and back
to the second-level menu.
Rover APIS
Set up the receiver as a rover station using
APIS service.
Click Enter button to enter the