7.3.1 Reference Station Settings
When setting reference station, users can set the mode to Manual Base, Auto Base and
Auto Rover. Users can also set the coordinates of the reference station and support Sample
for Average.
Several methods can be used to input the coordinates of the reference station. Users can
click [Acquire Current Position] to set the location of the reference station, which is not
accurate because it is the coordinates of the antenna phase center measured in signal
status. If users have known the coordinates of the antenna phase center, just input the
information manually.
In Sample for Average, the positioning limits are divided into Single Solution Coordinates
and Fix Solution Coordinates. Single means users can collect reference coordinates just in
single status while Fix means users can do that only in fix status. Sample Amount is the total
amount users set to be collected. Click [start], the system will take the average of collected
data and fill into the reference position column above automatically. The progress bar
represents the percentage of current collected numbers and total numbers.Click [Save] to
save current settings.