User's Guide

Step3Record
Record the name call, instrument SNnumber, instrument height, start observation time.
Step4Collect static data
Turn on the receiver, set the receiver to static mode, the receiver will automatically start recording static
after searching for enough satellites;
Receiver records static process do not touch scaffolding or instruments, try to avoid human interference,
arrange for special guards.
Step5Ends static recording
At the end of acquisition, turn off static mode and measure antenna height again from three directions
before closing, recording the average.
5.2 Static web page parameter settings
5.2.1 Static parameter settings
Visit the receiver page via the web page 192.168.1.1,select Record Settings in Record Settings, Select
Modifyrecord1, check Auto Record Static, collect interval select1s, height cutoff setting10, and record
duration1440minutes, storage formatRINEX, record date, record time, point storage, loop storage, single
acquisition all select No, other default, then click "Save" and click "Open" button to start recording static.
5.2.2 Parameter Description
Automatically record static --- set whether to automatically open this record after powering on Search
Sample intervals --- 1Hz to 60s are available
The height cut-off angle ---record1 can be set
The duration of the record --- the record duration of each file
The site name --- default to the SN number, which can be set
Antenna height, measurement method --- according to the actual scene settings
RINEX --- 2.11 and 3.0x are available in a compressed format
Start record date --- a specific date to open the record
Start Record Time --- Timed Start Storage (UTC Time)
Slope Height
Vertical Height
Control Points