User's Manual
ADSL MODEM USER MANUAL
- 13 -
3. Click “Bridging” Page -> choose
eoa-6
option for interface name -> click “Add” button -> click “Submit”
button.
4. Click “Commit & Reboot” label in the page Admin, shown as in Figure 2.3. Click “Commit” button to
save. When it shows “Changes Committed Successfully...” click “Reboot” button or turn off then turn on
the ADSL MODEM. The MODEM will work on the new parameters.
3.3 STATIC ROUTING CONFIGURATION
(
RFC1483 routing/RFC1577configuration
)
1. RFC1483 routing
a) ATM VC configuration
Use one of the ATM VCs which we had added in 3.2 for example: aal5-6 (VPI=0, VCI=33)
b) EOA configuration
− Only one PPP can be accepted by the MODEM as default router. So confirm there are no PPPs
in the “PPP” of Page “WAN”, shown as Figure 3.6.
− Click EOA label. The factory default configuration sets 6 EOAs (RFC1483 bridge). Add eoa-6
for example.
− Click “Add” button, the pop up window is shown as Figure 3.4
− Choose aal5-6 for Lower Interface option
−
Choose
enable
for Default Route option
− Fill the IP address, IP subnet mask and gateway IP address items with the parameters provided
by DSL ISP. Here we will use “202.117.118.25”, “255.255.255.0” and “202.96.199.133” as
examples.
− Don’t change other options, click “Submit” button, and the result window is shown as Figure 3.7
Figure 3.6