User's Manual

3
If over 0.33 Bar / 4.78PSI pressure loss in 16 seconds: the sensor will send data with quick
leakage icon immediately; If over 0.16bar/2.32PSI pressure loss in 8 seconds: the sensor
will send data without quick leakage icon immediately.
1.2.4 STATIONARY WORKING MODE
If the pressure is below 0.66Bar, the sensor will not send any data and enter into stationary
working mode.
1.2.5 HIGH TEMPERATURE WARNING MODE
If the temperature is over 80 , the sensor will send temperature data with high
temperature warning icon.
1.2.6 LOW FREQUENCE AWAKING MODE
Use the handled tool to awake the sensor to find out its ID number, pressure and
temperature data.
1.3 INSTALLATION TRANSMITTER
Before installation, make sure you identify each pair of transmitter and ID
module. We have two installation methods: magnetic installation method and patchy
installation method. For magnetic installation method, there is a pair of transmitters
& ID modules along with two magnets packed in a small box, they have the same ID
code. For patchy installation method, there is also a pair of transmitters & ID
modules along with a patch packed in a small box, they have the same ID code. For
example: DF102027.
Install the transmitter in the wheel with magnets or patch. Then install the ID
modules in the corresponding position of display and trailer ID box.
1.3.1 Installation Transmitter
1.3.1.1 Remove the wheel from the vehicle and then remove the tire. Clean the area where
the transmitter is to be installed.
1.3.1.2 Installation the transmitter