User manual

BTP-M280 User’s Manual
- 60 -
Interface Module.
6.6 Power interface definition
1) Pin definition
1: Positive pole (+24V)
2: CathodeGND
3: NC
2) Interface type
Printer end should use: Unetop DC-002 or equivalent
product.
User end should use: Unetop DP-002 or equivalent
product.
6.7 Cashdrawer definition
1) Electrical features
Driving voltage: DC 24 V
Driving current: Max 0.8 A (within 510 ms)
Cash drawer status inspection signal:
“L” = 00.5 V
“H” = 35 V
2) Cash drawer interface outlet uses RJ11 6P
connector.