User manual
BTP-R580 USER MANUAL
- 34 -
Fig6.6-2 Power socket
6.7 Signal definition of cash drawer interface
1) Electric characteristics
Driving voltage: DC 24 V
Driving current: Max. current is 1 A
The signal for checking cash drawer status:
“L” = 0~0.5 V “H” = 3.3 V
2) Cash drawer interface socket uses RJ-11 6P connector.
Fig. 6.7-1
3) Interface signal definition
No. Signal Functions
1 FG Frame
2 DRAWER 1 Driving signal of cash drawer1
3
DRSW Check signal for cash drawer status
4 VDR Cash drawer driving power
5
-
NC
6
GND Common port with circuit
Table 6.7-2