User Manual
ELECTRIC PRESSURE WASHER
12
The motor won't run or
stop running when it is
working.
The nozzle cannot spray
water or spray water in
low pressure.
Problem
Cause
Possible
Solution
1) No power supply or poor
connect between the plug
and socket.
1) Nozzle is clogged.
2) The checking valve
closes down.
3)There is air in the hose.
4) Water sealing worn off.
5) The filter net is clogged.
1) Examine the power
supply and make the plug
& socket well connected.
1) Clear the nozzle.
2) Run the pump with
water tap as water supply
for some minutes or
clean the checking valve.
3) Make firmly connecting
of the water inlet hose to
eject the air.
4) Replace the water seal.
5) Clear the filter net.
2) The switch or remote
control switch may be
broken, or the battery
depleted.
3) The voltage of the power
is too low.
4) Crankshaft and connect
rod won't lubricate well.
5) The capacitor broken.
2) Repair or replace the
switch, or replace the
battery.
3) Consult with the
electric supply.
4) Detach the fan cover
from the motor and turn
the motor around. If after
doing that it still won't
work, to agent for repair.
5) To the agent to replace
the capacitor.