Specifications

SGM Elettronica - Light Technology GB
User's manual 1.01 - 32 - Palco 3 - Palco 5
Stand-alone Programming
In permanent installations for architectural use, it may be necessary to use Palco fixtures in Stand-Alone mode (with
independent operation). This is very useful when the fixture has to run relatively simple scenes over a period of time,
without the aid of an external DMX controller, which could be difficult for inexperienced staff to operate. The
simplification of Palco’s operation ensures greater flexibility of use, even with important installations of a decorative-
architectural nature. Each Palco can therefore be programmed by means of 10 Programs, each with 10 scenes which are
completely adjustable as far as times and modes are concerned.
The “Scheduler” section also allows to organize the playback of programs already prepared on a weekly basis (day by
day from Monday to Sunday), deciding the start and finish time of playback of the Program. Each day can obviously
contain several events, for a maximum of 48 per week.
Should the installation involve a large number of fixtures, it’s possible to create a completely independent programmable
MASTER-SLAVE type system, which can involve a maximum of 30 fixtures. In this case, it will only be necessary to
program the MASTER (main) fixture, and all the fixtures connected to it will ruin the same program if configured as
SLAVES. During Master programming, it’s also possible to store various luminous statuses for several fixtures within each
scene of the program. Each on-board Master program is therefore also able to individually control all the SLAVE fixtures
scene by scene.
Everything is obviously controllable by means of the Scheduler, which enables the system controller to automate all the
events as required over a period of time without having to resort to external controllers every time.
Programming PALCO
ATTENTION !!
Palco programming is possible if the fixture isn’t receiving a DMX 512 or RS 232 signal.
Make certain that the fixture is not receiving DMX 512 or RS 232 signals and configure Palco as a “MASTER” (see.
“Master Configuration“
in the previous chapter).
Follow the steps described now for the programming:
Once Master status is enabled, “MASTER” appears on the display.
Step 1 - CHOOSING THE PROGRAM NUMBER
1. Use the UP/DOWN keys to find the “PROGRAMMER” menu
2. Press “Enter” for a few seconds, until the following appears: “PROGRAM=1”
3. If it is necessary to create a program other than number 1, press “Enter” again and
“PROGRAM=” will begin to flash
4. Use the UP/DOWN keys to choose the required program number from 1 to 5, then
Press “Enter” to exit the PROGRAM menu and confirm.
MASTER
PROGRAMMER
PROGRAM=1