Specifications

SGM Elettronica - Light Technology GB
User's manual 1.01 - 24 - Palco 3 - Palco 5
Menus
This chapter covers all the functions that can be accessed by the microcomputer’s menus. These functions allow to set
the fixture according to one’s needs, obtain information on its operation, test its various parts and lastly program it, if it
has to be used in Stand-alone mode.
The Up and Down keys on the front control panel enable users to scroll through the various menu items. In the
selected menu, they enable to modify the necessary parameters.
The ENTER key gives access to the selected menu, and once the necessary modifications have been carried out,
enables changes to be confirmed.
Menu Options Description
Addr 001 - 504 Fixture addressing
COLBALANCE - Access to the functions for setting the white balance
ON Enables the white balance of the COLBALANCE menu BALANCE
OFF Disables the white balance of the COLBALANCE menu
ON Enables power boost BOOST
OFF Disables power boost
R_h - Red LED elapsed time reading menu. Can be reset
G_h - Green LED elapsed time reading menu. Can be reset
B_h - Blue LED elapsed time reading menu. Can be reset
L_h - Overall fixture elapsed time reading menu.
DMX DMX signal selected SIGN
RS 232 RS 232 signal selected
BRIGH 100 – 53 – 40 – 27 – 20
13 – 6 – 0 (%)
Allows to adjust display brightness
Default configuration = 40 %
DSPLFLIP - Inverts display reading position
0 – 998 (sec) - UNL It’s possible to decide for how many seconds the fixture’s last channel
status has to be held in the event of there being no DMX signal (default =
UNL)
DMXDLY
UNL Always maintains the last channel status even in the event of no DMX
signal
DAY MON - TUE - WED -
THU - FRI - SAT- SUN
Sets the day of the week
C Hh : mm : ss Sets the on-board clock’s hours, minutes and seconds
SET Enables to set the fixture’s Default work parameters FACT
OFF FACT value during normal operation
SET Allows to reset the values of the parameters set immediately before
carrying out FACT=SET procedure
PREV
OFF PREV value during normal operation
TEST - Tests the correct operation of the physical channels of the fixture as
chosen
TEMPERATUR - Displays the current temperature of the head in degrees Centigrade or
Fahrenheit
ON Fixture in Master data transmission mode MASTER
OFF Fixture in NON-Master mode
SLAVEID 1 - 39 Configures the slave number the fixture is assigned to
ON Enables program playback as scheduled SCHEDL
OFF Disables program playback as scheduled
OFF Disables program playback PRGRUN
1 - 5 Enables playback of one of the five programs
PROGAMMER - Gives access to the programming functions of the five programs
SCHEDULER - Gives access to the programming functions of the Scheduler
ADDR Display default status after 8 seconds of not being used