User`s guide

L1 Controller Commands
007-3938-003 75
pbay dcport <DC port number 1 - 8>
pbay fru
pbay fru <0 for power bay, 1 - 6 for DPS>
pbay reset
pbay env
pbay env on|off
pbay init
pbay serial
Use the pbay command to view the status of the power bay (see Example 3-44).
Example 3-44 pbay Command Output
001r28-L1>pbay
Total current: 16.5 Amps (+/-11%)
Use pbay version to view the firmware version of the power bay (see Example 3-45).
Example 3-45 pbay version Command Output
001r28-L1>pbay version
PBay FW Version 00.18, Built 09/29/2001 14:00:00
Use the other commands in this set as follows:
Use pbay dps to view the status of all distributed power supplies (DPS).
Use pbay dps <powerbay number> to view the status of an individual distributed
power supply. The distributed power supplies are identified by a number ranging
from 1 to 6.
Use pbay dcport to view the status of all DC output ports.
Use pbay dcport <port number> to view the status for an individual DC port. The
ports are identified by a number ranging from 1 to 8.
Use pbay fru to view information about all the power bays and DPS FRUs.
Use pbay fru <powerbay number> to view information about the individual power
bay FRUs, use the number 0. To view information about a distributed power supply
FRU, use the numbers 1 through 6.