User`s guide
L1 Controller Commands
007-3938-003 67
USB: registered as remote
SMP-R: UART:UART_NO_CONNECTION
L1 booting...
[L1-0] ALERT: eeprom.c line 367 ; eeprom 0 checksum error.
USB: registered as remote
L1 booting...
[L1-0] ALERT: eeprom.c line 367 ; eeprom 0 checksum error.
USB: registered as remote
CTI-R: UART:UART_BREAK_RECEIVED
CTI-R: IRouter:read failed - read error
USB-R: USB:device was reset
Use log clear or log reset to empty the log. Example 3-39 shows sample output.
Example 3-39 log reset Command Output
001c003-L1>log reset
log reset.
Use log insert <entry> to write a line in the log. The variable <entry> is text to enter
into the log. Example 3-40 shows sample output from the log Start the Test
command.
Example 3-40 log insert Start the Test Command Output
001c003-L1>log insert Start the Test
log entry made.
Used on all bricks.
margin
Use the margin command to show the margin status of all voltages.
• margin|mgn
All voltages margin status
• margin|mgn default|low|norm|high
Set all voltages to read-only memery (ROM) defaults
• margin|mgn gbrick default|low|norm|high
Set all G-brick voltages to ROM defaults