User`s guide

56 007-3938-003
3: L1 and L2 Controller Commands
flash
The following flash command set provides the status of and updates of the firmware
images stored in flash memory.
flash status
flash status verbose
flash default <a|b>
flash default current
flash default new
flash default old
flash default reset
Use flash status to view the status of the two firmware images stored in flash
memory. Example 3-23 shows sample output. Each image has a checksum value that
indicates whether an image is valid.
Example 3-23 flash status Command Output
001c07-L1>flash status
Flash image A currently booted
Image Status Revision Built
----- -------- ---------- -----
A default 0.7.27 04/28/2000 13:06:43
B valid 0.8.0 05/24/2000 10:50:23
Use the other commands in this set as follows:
Use flash status verbose to display an expanded version of the flash status.
Use flash default <a|b> to set firmware image A or firmware image B as the
default image that the system controller uses when booting.
Use flash default current to set the current image as the default flash image.
Use flash default new to set the new image as the default flash image.
Use flash default old to set the old image as the default flash image.