User`s guide
L1 Controller Commands
007-3938-003 53
PIMM0 1.5V Enabled 10% 1.350/ 1.650 20% 1.200/ 1.800 1.495
PIMM0 3.3V aux Enabled 10% 2.970/ 3.630 20% 2.640/ 3.960 3.320
PIMM0 5V aux Enabled 10% 4.500/ 5.500 20% 4.000/ 6.000 4.914
PIMM0 12V bias Enabled 10% 10.800/ 13.200 20% 9.600/ 14.400 12.125
PIMM1 SRAM Disabled 10% 2.970/ 3.630 20% 2.640/ 3.960 12.125
PIMM1 CPU Disabled 10% 1.710/ 2.090 20% 1.520/ 2.280 12.125
PIMM1 1.5V Disabled 10% 1.350/ 1.650 20% 1.200/ 1.800 12.125
PIMM1 3.3V aux Disabled 10% 2.970/ 3.630 20% 2.640/ 3.960 12.125
PIMM1 5V aux Disabled 10% 4.500/ 5.500 20% 4.000/ 6.000 12.125
PIMM1 12V bias Disabled 10% 10.800/ 13.200 20% 9.600/ 14.400 12.125
Description State Warning RPM Current RPM
------------- --------- -------------- -------------
FAN 0 Enabled 2160 2421
FAN 1 Enabled 2160 2421
FAN 2 Enabled 2160 2404
Advisory Critical Fault Current
Description State Temp Temp Temp Temp
-------------- ---------- -------- -------- -------- ---------
TEMP 3 Enabled 30C/ 86F 35C/ 95F 40C/104F 26c/ 78F
TEMP 5 Disabled 30C/ 86F 35C/ 95F 40C/104F 0c/ 32F
The environmental monitoring and auto start status area has two statements. The first
statement describes the current state of environmental monitoring. The environmental
monitoring state is one of the following:
• “disabled - initialization error”
• “disabled - configuration error”
• “disabled - start error”
• “disabled”
• “disabled - unknown error (0x00)”
• “running”
The second statement describes the current state of the auto start. The auto start state is
“enabled” or “disabled.”