User`s guide

42 007-3938-003
3: L1 and L2 Controller Commands
brick
The following brick command set provides the status of the brick and sets the brick
location and type.
brick
brick type <str>
brick rack <rack number>
brick slot <slot number>
brick rackslot <rack number> <slot number>
brick partition none
brick partition <partition number>
Note: For this command set, you can use bay or upos instead of slot, rs instead of
rackslot, and part or p in the place of partition.
Use the brick command to determine the brick location and type. Example 3-3 shows
sample output.
Example 3-3 brick Command Output
001c07-L1>brick
rack: 001 slot: 07 partition:0type: C source: EEPROM
Use brick rack <rack number> to set the rack number where the brick is located.
Example 3-4 shows sample output.
Example 3-4 brick rack <rack number> Command Output
001c07-L1>brick rack 1
brick rack set to 001.
Use brick slot <slot number> to set the brick slot number in the rack. The variable
<slot number> is a unit number from 01 to 39. Example 3-5 shows sample output.