User`s guide
108 007-3938-003
3: L1 and L2 Controller Commands
Example 3-84 power Command Output
L2>power
001i21:
power appears on
001r19:
power appears on
001c07:
power appears on
001c10:
power appears on
Use rack <rng> slot <rng> power to view the power status of a specified brick. Use
rack <rng> slot <rng> power up or rack <rng> slot <rng> power down to
power up or power down specified bricks. The variable <rng> following rack is one or
more rack numbers and the variable <rng> following slot is one or more slot numbers.
Example 3-85 shows sample output.
Example 3-85 rack <rng> slot <rng> power Command Output
L2>r 1 s 19 power
power appears on
Note: For the <rng> variable, you can enter a single number, or two numbers separated
by a hyphen to indicate a range, or numbers separated by commas to indicate separate
items. For <rng>, you can also enter an asterisk or the word “all” to select all the items
available.
Use power summary to display a power status summary. Use rack <rng> slot <rng>
power summary to display the power status summary for specified bricks.
Example 3-86 shows sample output.
Example 3-86 power summary Command Output
L2>power summary
all 2 bricks appear powered off
margin: 1 default, 0 low, 0 normal, 0 high, 0 custom, 0 other
L2>
Use power delay to show the delay between power commands. Use power delay
<milliseconds> to set the delay between power commands in milliseconds.