User`s guide
106 007-3938-003
3: L1 and L2 Controller Commands
nvram reset
The nvram reset command returns the NVRAM settings of the L2 controller to the
factory default settings.
pbay
Use pbay config to report the bricks connected to each power bay. Use pbay
<command> to send a specified command to one L1 controller connected to each power
bay.
ping
Use the following ping command set to set the ping function between L2 controller and
L2 controllers or L2 controller and L1 controllers.
• ping
• ping min <frequency in seconds>
• ping max <frequency in seconds>
• ping l2 <frequency in seconds>
• ping sender <1 or 0>
• ping l1 <frequency in seconds>
• ping reset
Use the commands in this set as follows:
• Use ping to display the L2 controller to L2 controller or L2 controller to L1
controller ping configurations.
• Use ping min <frequency in seconds> to set the L2 controller to L2 controller ping
response to a minimum specified in <frequency in seconds>.
• Use ping max <frequency in seconds> to set the L2 controller to L2 controller ping
response to a maximum specified in <frequency in seconds>.
• Use ping l2 <frequency in seconds> to set the L2 controller to L2 controller ping
frequency.