Specifications

290
Appendix B: Care and Cleaning of the Compression Connector
3. Hold the can in a vertical position.
4. Place or hold the XIO board so that the rounded edge of the compression connector
faces up. Note that the rounded edge is completely closed, so that air cannot flow
into the connector, whereas the squared edge has an opening.
Caution: Spraying into the squared (open) edge of the connector can destroy it.
5. Position theXIO board atan angle to the can, so that the tip of the can’s applicator is
1 to 2 inches away from the first (topmost) row of pads. Do not allow the applicator
to touch the pads. When you spray, the air hits each pad and flows downward.
6. Start spraying. Asyou spray, move the spray along the lengthof the connector until
the entire length has been sprayed. Move down a few rows and again spray along
the entire length.
Note: Donotshakethecan.Stopsprayingif anyvisiblematerial(for example,foam)
appears. This foam will blow away once you resume spraying just air.
7. Repeat until all the pads have been sprayed.
8. When you finish, cover the compression connector with its cap or immediately
install the board in an XIO slot.