Specifications

Guidelines for Cleaning the Compression Connector
289
To remove pollutants, follow these instructions:
1. Obtain a can of dry compressed air or inert gas. The Envi-ro-tech Duster 1671
productmanufacturedby TECHSPRAY(Inthe USA, telephone806-372-8523) works
extremely well for this application.
Caution: Do not use a cleaning product that contains any of the following
ingredients: halogenated hydrocarbons, aromatic hydrocarbons, ethers, sulfur,
ketones, or solvents of any kind. These substances cause irreparable damage to the
connector’s surface.
2. Prepare the can for use, as instructed on the can. For example, if a tube is provided,
attach it to the can’s dispensing mechanism.
Figure B-2 Spraying the Compression Connector