User guide
52 007-5837-001
A: Power and Environmental Specifications
Environmental Specifications
Table A-2 lists the system-level operation and non-operating environmental limits.
Table A-2 Environmental Specifications
Attribute Limits
Operating temperature +10
ºC to +35ºC with the maximum rate of change not to exceed 10ºC per hour
Non-operating
temperature
-40
ºC to +70ºC
Operating humidity range 20%–80%, non-condensing
Non-operating humidity 8%–80%, non-condensing at 35ºC
Acoustic noise Sound power:
7.0 BA in operating condition at typical office ambient temperature
(23ºC +/– 2ºC).
Shock, operating Half sine, 2 g peak, 11 milliseconds
Shock, unpackaged Trapezoidal, 25 g, velocity change 136 inches/second (40 lbs to less than 80
lbs)
Shock, packaged Non-palletized free fall in height 24 inches (40 lbs to less than 80 lbs)
Vibration, unpackaged 5 Hz to 500 Hz, 2.20 g RMS random
ESD +/-12 KV, except I/O port +/- 8 KV per test specification
System cooling
requirement in BTU/Hr
460 Watt Max – 1570 BTU/hour
750 Watt Max – 2560 BTU/hour