Technical data

Chapter 8: Specifications of the E5500 Controller-Drive Tray 61
E5500
Controller-Drive
Tray Shipping
Dimensions
Table 40 Shipping Carton Dimensions for the E5512 and E5524 Controller-Drive Trays
E5500
Controller-Drive
Tray
Temperature
and Humidity
NOTE Converting Maximum Rate of Change requires converting between Fahrenheit
and Celsius first, and then subtracting the difference.
Table 41 Temperature Requirements and Humidity Requirements for the E5512
and E5524 Controller-Drive Trays
Controller-Drive Tray Height Width Depth
E5512 controller-drive tray with
twelve 3.5-in. drives
24.13 cm (9.5 in.) 63.50 cm (25 in.) 58.42 cm (23 in.)
E5524 controller-drive tray with
twenty-four 2.5-in. drives
24.13 cm (9.5 in.) 68.58 cm (27 in.) 58.42 cm (23 in.)
Condition Parameter Requirement
Temperature Operating range (both cabinet
and subsystem)
10°C to 35°C (50°F to 95°F)
Maximum rate of change 10°C per hour (18°F) per hour
Storage range –10°C to 50°C (14°F to 122°F)
Maximum rate of change 15°C per hour (27°F) per hour
Transit range –40°C to 60°C (–40°F to 140°F)
Maximum rate of change 20°C per hour (36°F) per hour