Setup guide
84 007-5923-001
B: System Specifications and Regulatory Overview
Table B-2 describes the technical specifications for the SGI MIS JBOD platform.
Table B-2 MIS JBOD Enclosure Operating and Environmental Specifications
Attribute Specification
Overview
Profile 4U Standard-depth chassis
Product type SGI MIS JBOD Unit
Connectivity Up to four SGI MIS NAS JBOD units per SGI NAS Server
Mount –Standard 19-inch rack-compatible rail mount (weight-dependent)
–SGI 19-inch Destination Rack (D-Rack), 42U
–Up to 5 chassis maximum per D-Rack
Chassis Dimensions
Height 6.94" (176 mm)
Width 16.9" (429.2 mm)
Depth 36" (914.4 mm)
Max weight 220 lbs.
Power
AC Input 100–240 VAC (50-60Hz), single or three phase
Safety –UL/CSA certified to UL6050-1
–CE/CB certified to EN60950/IEC60950
EMC –North America FCC Class A
–Europe EN55022/EN55024
Operating Environment
Operating
temperature
range
–41
º to 95º F (5º to 35º C)
Non-operating
temperature
range
-40
º to 140º F (minus 40º to 60º C)