Specifications

SCPI Command Operation SG Series Programming
6-30 M550129-03 Rev G
Command Description
SCPI
:CALCulate
Calculates the value of the gain and offset for voltage
measurements.
N
:GAIN <NRf>
Sets the value of the gain for voltage measurements.
N
:GAIN?
Returns the value of the gain for voltage measurements.
N
:OFFSet <NRf>
Sets the value of the offset for voltage measurements.
N
:OFFSet?
Returns the value of the offset for the voltage
measurements.
N
:POINt <1|2>
<NRf>
Sets the voltage measurement calibration point (1 or 2).
The actual output voltage is measured with an external
meter.
N
:MODel
Calibrate Model subsystem
N
:LASTCALDATE<NRf>
(Ethernet only) Sets the date last calibrated;
format: MM DD YYYY (space after MM and DD required)
N
:LASTCALDATE?
(Ethernet only) Returns the date last calibrated.
N
:NEXTCALDATE<NRf>
(Ethernet only) Sets the date next calibration is required;
format: MM DD YYYY (space after MM and DD required)
N
:NEXTCALDATE?
(Ethernet only) Returns the date next calibration is
required.
N
:POWERON <String>
Sets the default output enable condition at power on.
Input format:
“ON:INIT” enables the output at next power on
“OFF:INIT” disables the output at next power on
NOTE: Quotations are required in the command string.
N
:POWERON?
Returns the status of the output enable condition at power
on
N
:RESET <String>
Sets the default output enable condition when the *RST
command is issued.
Input format:
“ON:INIT” enables the default output
“OFF:INIT” disables the default output
NOTE: Quotations are required in the command string.
N
:RESET?
Returns the status of the default output enable condition
when the *RST command is issued
N
:OUTPut
Calibrate Output subsystem
N
:CURRent
Calibrate Output Current subsystem
N
:CALCulate
Calculates the value of the gain and offset for output
current.
N
:DAC <NR1>
Sets the output of the output current D/A converter.
N
:FIVEPOINT
<1|2|3|4|5>
(Ethernet only) Sets output current value for each
calibration point (1-5)
N
:FIVEPOINT?
(Ethernet only) Returns the entered values for 5-point
calibration.
N
:GAIN <NRf>
Sets the value of the gain for the output current.
N
:GAIN?
Returns the value of the gain for the output current.
N
:OFFSet <NRf>
Sets the value of the offset for the output current.
N
:OFFSet?
Returns the value of the offset for the output current.
N
:POINt <1|2>
<NRf>
Sets the current output calibration point
(1 or 2). The actual output current is measured with an
external meter.
N