Specifications

SCPI Command Operation SG Series Programming
6-26 M550129-03 Rev G
6.11 TRIGGER SCPI COMMAND SUBSYSTEM
This section describes the programming soft trigger function.
6.11.1 TRIGGER SCPI Command Summary
TRIGger
:ABORt
:RAMP
:TYPE <1|2|3>
6.11.2 TRIGGER SCPI Command Reference
The letter “C” in the “SCPI” column means that the command syntax is
SCPI compliant; an “N” in the “SCPI” column means that the command
syntax is not part of the SCPI definition.
Command Description SCPI
TRIGger
Trigger subsystem.
C
:ABORt
Stops the execution of a currently running trigger function, and
clears all settings of voltage and current.
N
:RAMP
Executes voltage or current ramping function previously
programmed by the SOURce command, i.e.,
SOURce:VOLTage:RAMP
SOURce:CURRent:RAMP
N
:TYPe<1|2|3>
Executes voltage and current values previously programmed by
the SOURce command i.e.,
SOURce:VOLTage:LEVel:TRIGger
SOURce:CURRent:LEVel:TRIGger
Valid arguments are 1 (Voltage),
2 (Current), or 3 (Both).
N