Specifications

SCPI Command Operation SG Series Programming
6-14 M550129-03 Rev G
Command Description
SCPI
:ALL?
Returns the ramping status of all channels. N
:HTRIGgered <NRf>
Sets the value of the output current to ramp to be
implemented when the hardware trigger is received.
N
:HTRIGgered?
Returns the value of the output current to ramp to be
implemented when the hardware trigger is received.
N
:TRIGgered <NRf>
<NRf>
Sets the output current to ramp from the present value to
the specified value (first argument) in the specified time
(second argument) upon the trigger command. See Ramp
description below.
C
:TRIGgered?
Returns the value that the output current is to ramp to (first
value) and the time that it is to ramp (second value) upon
the trigger command.
C
:TRIGgered
Sets the output voltage to the values stored by the
SOURce: CURRent:TRIGger:AMPLitude command.
C
:TRIGgered?
Returns the current level that will be set upon receipt of the
trigger.
C
:CLEar
Clears the value stored by the
SOURce:CURRent:TRIGger:AMPLitudecommand.
C
:AMPLitude <NRf>
Stores the value of the output current to be set when the
SOURce: CURRent:TRIGGered command is sent.
C
:AMPLitude?
Returns the stored value of the output current to be set
when the SOURce: CURRent:TRIGGered command is
sent.
C
:POWer (in SGI only)
:POWer? (in SGI only)
See Section 6.13.2.
:TIMeout?
Returns the integer value 1 (timeout since last query) or 0
(no timeout) of the timeout status of the channel.
N
:VOLTage
Sets the output voltage of the supply in volts (default) or in
millivolts.
C
:VOLTage?
Returns the output voltage of the supply in volts or in
millivolts.
C
[:LEVel]
Sets the output voltage of the supply in volts (default) or in
millivolts.
C
[:LEVel?]
Returns the output voltage of the supply in volts or in
millivolts.
C
[:IMMediate]
Sets the output voltage of the supply in volts (default) or in
millivolts.
C
[:IMMediate?]
Returns the output voltage of the supply in volts or in
millivolts.
C
[:AMPLitude]
<NRf>
Sets the output voltage of the supply in amps (default) or in
milliamps.
C
[:AMPLitude?]
Returns the output voltage of the supply in amps or in
milliamps.
C
:LIMit
Sets the upper soft limit on the programmed output voltage.
The soft limit prevents the supply from being inadvertently
programmed above the soft limit, thus providing a method
for protecting the load against damaging voltages.
C
:LIMit?
Returns the upper soft limit set on the programmed output
voltage.
C
[:AMPLitude]
<NRf>
Sets the upper soft limit on the programmed output voltage. C
[:AMPLitude?]
Returns the upper soft limit on the programmed output
voltage.
C