Specifications

Ethernet Features, Functions and Specifications SG Series Programming
4-4 M550129-03 Rev G
4.3.2 Ethernet Configuration Factory Defaults
PARAMETER DEFAULT
Host Name SGx<base model>-<last four digits of serial number>
Description Sorensen Power Supply SGx<base model>
IP Address
DHCP-acquired (Primary default*) If DHCP absent,
assigned via Auto-IP (Secondary default*)
IP Addressing mode
DHCP-acquired (Primary default*)
Subnet Mask
DHCP-acquired (Primary default*) If DHCP absent,
assigned via Auto-IP (Secondary default*)
Gateway 0.0.0.0
DNS Server 0.0.0.0
Listening Port 9221
User ID admin
Password password
Ping Echo On
* Primary/Secondary defaults:
The Ethernet interface provides the opportunity to set both a Primary and
a Secondary IP configuration in the IP Configuration page (Section 5.5.2).
If
the Primary fails, the system defaults to the Secondary configuration.
However, both setting “DHCP-acquired” and selecting “Auto IP Enabled”
together in the Primary configuration, prevents the power supply from
trying the Secondary configuration. Please see “TCP/IP Configuration”
and “Auto IP Enabled” under IP Configuration, Section 5.5.2 for more
detail.
4.3.3 Programming Resolution
SGA SGI
Voltage 0.002% of full scale 0.002% of full scale
Current 0.002% of full scale 0.002% of full scale
Overvoltage
Protection
0.002% of full scale (full scale is 110% of
max output voltage.)
0.002% of full scale (full
scale is 110% of max
output voltage.)
4.3.4 Programming Accuracy
SGA SGI
Voltage ± (0.1% of maximum output voltage) ± (0.1% + 0.1% of full scale)
Current ± (0.25% of full scale output current ± (0.1% + 0.4% of full scale)
Overvoltage
Protection
± (0.5% of max output voltage)
± (0.5% + 0.5% of full scale)
(full scale 110% of max. output
voltage)