SG Series Programming Ethernet Features, Functions and Specifications
M550129-03 Rev G 4-3
4.2.2 Programmable Functions
Output voltage and current
Soft limits for voltage and current
Overvoltage protection
Output enable/disable
Maskable fault interrupt
Hold and trigger
External relay control
Full calibration
4.2.3 Readback Functions
Measured voltage and current
Voltage and current settings
Soft voltage and current limits
Overvoltage protection setting
Status and Accumulated Status registers
Programming error codes
Fault codes
Manufacturer, power supply model, and firmware version identification
4.3 SPECIFICATIONS
(SUBJECT TO CHANGE WITHOUT NOTICE)
4.3.1 Ethernet/LAN Configuration
Ethernet: IEEE-802.3 compliant
Medium: 10/100 base-T
Connection Monitoring: Media Sense supported
Protocol: TCP/IP, IPV4
ICMP (ping server): Enable (default)/Disable
IP Address Assignment: Automatic via DHCP (Primary default), Static,
or Automatic Private IP Addressing (Auto-IP, Secondary default)
VXI-11 Discovery: Supported
Security: Password protected access, and selective permissions for
each user